Installer / Service Manual BURNiT PM Comfort
Plus
32 –ЕN
6.7.7. Extinguishing Thermostats Menu
TP 13
Settings for each Combustion Phase/Power of the Exhausting Temperature under
which, after the Pre-Extinguishing time T14, the stove goes in Extinguishing for no
flame. These values occur with the Th03 Thermostat
Code
Description
Probe
Min.
Max.
U
Def.
Th35
Power 1
Exhausting
5
900
[°C]
45
Th36
Power 2
Exhausting
5
900
[°C]
45
Th37
Power 3
Exhausting
5
900
[°C]
45
Th38
Power 4
Exhausting
5
900
[°C]
45
Th39
Power 5
Exhausting
5
900
[°C]
45
Th40
Modulation Power
Exhausting
5
900
[°C]
45
Th43
Power 1
Exhausting
5
900
[°C]
45
6.8. Functioning States
6.8.1. Off
Timer
Controls
Combustion
Fan
Auger
Igniter
If Exhausting
Temp. >
Th01
→ goes in
Extinguishing
OFF
OFF
OFF
If Water Temp.
>
Th25
→ goes in
Block
6.8.2. Check Up
Timer
Controls
Combustion
Fan
Auger
Igniter
T01
If Exhausting
Temp. >
Th09
→ goes in
Normal
Max Speed
OFF
OFF
6.8.3. Pre-Heating
Timer
Controls
Combustion
Fan
Auger
Igniter
T02
If Exhausting
Temp. >
Th09
→ goes in
Normal
U01
OFF
ON
6.8.4. Pre-Loading
Timer
Controls
Combustion
Auger
Igniter