6.7. Installer’s Menu
Push contemporary buttons
P2+P4
and choose
TPAr
to enter in the
installer menu,
protected by password
TPAr
6.7.1. Auger Menu
Setting of
Auger TimeON
defined for each phase/power in the
Auger Period P05
TP O1
If a value is set =
0
the Auger is disabled for the corresponding Power/Phase
If a value is set ≥
P05
the Auger works continuously for corresponding
Power/Phase
The TimeON regulation is settable as steps of 0.1 seconds
The set or calculated values are automatically limited in the threshold
P05
and
P27
Code
Description
Min
Max.
U
13kW
25kW
C01
Auger TimeON Ignition
0
60
[s]
2
2
C02
Auger TimeON Stabilization
0
60
[s]
2
2
C03
Auger TimeON Power 1
P27
60
[s]
1
2
C04
Auger TimeON Power 2
P27
60
[s]
1,6
2,4
C05
Auger TimeON Power 3
P27
60
[s]
2,3
3,6
C06
Auger TimeON Power 4
P27
60
[s]
2,9
4
C07
Auger TimeON Power 5
P27
60
[s]
3,9
5,2
C08
Auger TimeON during Periodic
Cleaning
0
60
[s]
2
2
C10
Auger TimeON Second Ignition
0
60
[s]
0
0
C11
Auger TimeON Modulation
P27
60
[s]
1.3
2
P05
Total Time Auger Period
4
60
[s]
10
10
P15
Correction Step value of the value
Auger TimeON
1
20
[%]
2
2
P27
Minimum Auger TimeON
0
60
[s]
0,1
0,1
6.7.2. Combustion Fan Menu
Setting of the Combustion fan speed for each power/phase of functioning.
TP O2