Installer / Service Manual BURNiT PM Comfort
Plus
22 –ЕN
6.5.4. Manual Pellet Loading
The long pressure of button
P2
activates
the Pellet Manual Loading with activation
of Auger engine in continuous way. The
bottom display shows the actual function.
The upper display shows the passed
loading time.
To stop the loading push any button.
The loading stops automatically after 300
seconds.
6.5.5. Pellet Loading Correction
The activation is with a long pushing of the
button
P3.
The bottom display shows
PELL.
The Display
D1
shows the blinking value.
With buttons
P3 / P4
the blinking value
increases or decreases.
The values are between the range
– 7 ÷ 7.
The default value is ‘
0
’.
After 3 seconds the new value is
memorised and the display shows as
normal.
6.5.6. Combustion Fan Speed Correction
The activation is with a long pushing of the
button
P2
.
The bottom display shows
UEnt.
The Display
D1
shows the blinking value.
With buttons
P3 / P4
the blinking value
increases or decreases.
The values are between the range
– 7 ÷ 7
.
The default value is ‘
0
’.
After 3 seconds the new value is memorised
and the display shows as normal.
Содержание BURNiT PM Comfort 13 Plus
Страница 16: ...Installer Service Manual BURNiT PM Comfort Plus 16 N 6 2 Wiring controller Version 1 V1...
Страница 17: ...Installer Service Manual BURNiT PM Comfort Plus 17 N 6 3 Wiring controller Version 2 V2...
Страница 42: ...Installer Service Manual BURNiT PM Comfort Plus 42 N 6 9 9 Pressure Sensor Configuration...