Installer / Service Manual BURNiT PM Comfort
Plus
13 –ЕN
Table: European Certification of Wood Pellets for Heating Purposes:
Parameters
Measures
ENplus-A1
ENplus-A2
EN-B
Diameter
mm
6 (± 1)
8 (± 1)
6 (± 1)
8 (± 1)
6 (± 1)
8 (± 1)
Length
mm
15 ≤ L ≤ 40 1)
15 ≤ L ≤ 40 1)
15 ≤ L ≤ 40 1)
Bulk density
kg / m
2
≥ 600
≥ 600
≥ 600
Calorific value
MJ / kg
≥ 16,5-19
≥ 16,3-19
≥ 16,0-19
Humidity
Ма .-%
≤ 10
≤ 10
≤ 10
Dust
Ма .-%
≤ 1 3)
≤ 1 3)
≤ 1 3)
Mechanical strength
Ма .-%
≥ 97,5 4)
≥ 97,5 4)
≥ 96,5 4)
Ash
Ма .-% 2)
≤ 0,7
≤ 1,5
≤ 3,5
Ash melting point
°C
≥ 1200
≥ 1100
-
Content of chlorine
Ма .-% 2)
≤ 0,02
≤ 0,02
≤ 0,03
Content of sulfur
Ма .-% 2)
≤ 0,03
≤ 0,03
≤ 0,04
Content of nitrogen
Ма .-% 2)
≤ 0,3
≤ 0,3
≤ 1,0
Content of copper
mg / kg 2)
≤ 10
≤ 10
≤ 10
Content of chromium
mg / kg 2)
≤ 10
≤ 10
≤ 10
Content of arsenic
mg / kg 2)
≤ 1,0
≤ 1,0
≤ 1,0
Content of cadmium
mg / kg 2)
≤ 0,5
≤ 0,5
≤ 0,5
Content of mercury
mg / kg 2)
≤ 0,1
≤ 0,1
≤ 0,1
Content of lead
mg / kg 2)
≤ 10
≤ 10
≤ 10
Content of nickel
mg / kg 2)
≤ 10
≤ 10
≤ 10
Content of zinc
mg / kg 2)
≤ 100
≤ 100
≤ 100
1) Not more than 1% of the pallets must be longer than 40 mm, maximum length 45 mm;
2) Dry volume;
3) Particles <3.15 mm, fine dust particles, before delivery of the goods;
4) For measurements with lignotester the maximum allowed value ≥ 97,7 weight %.
When purchasing pellets, ask for conformity declaration and certificate issued
by an accredited laboratory and make sure the fuel meets the requirements
indicated in the manual. If you purchase large amount of pellets (bulk supply
for the entire heating season for example), ask your supplier to provide
accurate and true information about the storage conditions.
We recommend to use pellet with size of 6 - 8 mm. Density 600 - 750 kg/m
3
heating
value 4.7-5.5 kWh/kg. Ash content – less than 1% and moisture content up to 8%, EN
14961-2:2011.