Installer / Service  Manual   BURNiT PM Comfort 
Plus 

4 –ЕN 

or objects because of wrong installation or misuse. 
 8.  After  removing  the  packaging  material  the  end  user  must  check  up  if  all  the 
parts/units  are  available  and  if  something  is  missing  he  should  notify  the  seller  in 
order to receive the missing part. 
9.  Only  original  parts  must  be  used  for  servicing.  Contact  an  authorized  service  for 
the products BURNiT. 
10.  Obligatory  maintenance  –  the  pellet  stove  must  be  cleaned  immediately  after 
each consumption of certified pellets between 800 kg to 1000 kg or if usage is less at 
least once a year. This maintenance must be performed by an authorized by BURNIT 
service  center.    As  long  as  the  pellet  stove  is  in  its  warranty  period  all  the 
maintenance  and  service  must  be  performed  by  the  authorized  service  who  has 
performed the initial installation. 
 

For safety precautions the following rules must be strictly followed: 
 

 - The pellet stove must not be operated by children or people with disabilities.  
 - It is forbidden to install the pellet stove in wet or moist spaces such as bathroom, 
laundry etc. It is forbidden to touch the pellet stove with wet hands or feet. 
 -  It  is  forbidden  to  change  or  not  to  follow  the  safety  precautions  without 
permission by the authorized service /installer BURNiT. 
 - The power cable must be protected from damage or disconnection.  
 - Children or people with disabilities are forbidden to access unattended the room 
where the pellet stove is installed.  
 - The door of the pellet stove must be closed when the product is in working mode. 
 - Avoid direct contact with the hot surfaces of the pellet stove. 
 - Check for difficulties when starting the pellet stove before the start of the heating 
season or in cases when the product has not been used for a long time. 
 -  The  pellet  stove  is  designed  to  work  even  in  extreme  weather.  Still  in  case  of 
strong  wind  or  very  chill  weather  the  safety  system  of  the  product  may 
automatically  turn  of  the  pellet  stove.  In  that  case  the  end  user  must  notify 
authorized service /installer BURNiT. It is not recommended to deactivate or restart 
the safety functions of the product at your own. 
 - Stove installation room must be equipped with fire extinguisher in case of fire in 
the exhaust gases tube 

 

 
 
 
 
 
 

Содержание BURNiT PM Comfort 13 Plus

Страница 1: ...f PELLET STOVE with water jacket Series BURNiT PM Comfort Plus 13kW 25kW NES New Energy Systems Ltd 12 Madara Blvd 9700 Shumen Bulgaria tel 359 54 874 536 359 54 874 555 fax 359 54 874 556 e mail serv...

Страница 2: ...st gas system connecting the pellet stove to chimney 10 3 7 Roof installation of exhaust gas pipe 11 3 8 Connection to the power supply 11 4 Fuel 12 5 Exploitation of pellet stove 14 5 1 Safety precau...

Страница 3: ...wing safety precautions 1 We recommend to the authorized installer not to leave bare wires not entirely fit into the terminals To prevent the contact of bare wires with other parts 2 The installation...

Страница 4: ...ll the pellet stove in wet or moist spaces such as bathroom laundry etc It is forbidden to touch the pellet stove with wet hands or feet It is forbidden to change or not to follow the safety precautio...

Страница 5: ...carefully the documentation and do not throw away In case of visual defect damage or missing part notify immediately your seller 2 2 Description of pellet stove Pellet stove BURNiT PM Comfort Plus 13...

Страница 6: ...g air tube 2 3 Technical parameters Model PM 13 kW 25 kW Height mm 900 1100 Width mm 530 580 Depth mm 520 680 Weight kg 120 180 Flue exhaust gas tube diameter mm 80 80 Exhaust gas temperature 180 180...

Страница 7: ...ant for safety use of pellet stove Any mistakes done during the installation are not covered by the MANUFACTURER It is obligatory the installation the first start and the maintenance of the pellet sto...

Страница 8: ...opening for the fresh air must be minimum 100 cm2 and there should not be any obstacles on its way Fresh air could be taken also from other room which has its own constant ventilation and no other pel...

Страница 9: ...gh pressure and temperature 200 C 250 C recommended thickness of the pipes no less than 1mm In case you want to connect the pellet stove to the already existing exhaust gas system chimney its conditio...

Страница 10: ...Installer Service Manual BURNiT PM Comfort Plus 10 N 3 6 Diagrams for installing the exhaust gas system connecting the pellet stove to chimney Diagrams are an example only...

Страница 11: ...stance between the tube and other obstacles walls trees and others must not to be less than 10 m If the distance is less than 10m the height of the tubes must be 1m above the obstacles walls trees etc...

Страница 12: ...act on the production costs of food products or ethyl alcohol ethanol The raw material is processed under high pressure and temperature and is pressed to produce small size cylindrical pellets The pro...

Страница 13: ...ent of mercury mg kg 2 0 1 0 1 0 1 Content of lead mg kg 2 10 10 10 Content of nickel mg kg 2 10 10 10 Content of zinc mg kg 2 100 100 100 1 Not more than 1 of the pallets must be longer than 40 mm ma...

Страница 14: ...ode Beware of hot surfaces danger of burns Do not leave the children and disabled people unattended close to the product It is forbidden the children and disabled people to operate the pellet stove It...

Страница 15: ...ferent stoves and installations Product composition Control Board with 4 fixing points solid and sure Extractable connectors Exhaust gas temperature probe up to 500 C Room Temperature Probe Stove boil...

Страница 16: ...Installer Service Manual BURNiT PM Comfort Plus 16 N 6 2 Wiring controller Version 1 V1...

Страница 17: ...Installer Service Manual BURNiT PM Comfort Plus 17 N 6 3 Wiring controller Version 2 V2...

Страница 18: ...t used 12 13 Safety Pressure Switch Input HV2 Contact ON OFF Normally closed To Bypass if not used 14 15 Red Exhausting Temperature Probe Thermocouple K 500 C Max 16 Green 17 Probe or Room Thermostat...

Страница 19: ...2 Work Combustion Power set Combustion power change D3 Stove Thermostat set Momentary temperature in stove water jacket Stove Thermostat change Change of temperature in stove water jacket 2 Buttons Ke...

Страница 20: ...r Error No Encoder Signal in case of P25 1 or 2 Block Encoder Error Combustion Fan regulation failed in case of P25 1 or 2 Block Failed Ignition Block Lack of Voltage Supply Block Lack of fuel Block D...

Страница 21: ...The Extinguishing finished OFF state is signaled by the fix led L3 6 5 2 Combustion Power Setting Click button P2 the display D2 blinks With other click of the button P2 the power is changed according...

Страница 22: ...ng of the button P3 The bottom display shows PELL The Display D1 shows the blinking value With buttons P3 P4 the blinking value increases or decreases The values are between the range 7 7 The default...

Страница 23: ...ure UF Combustion Fan Speed RPM Volt HF02 Product Code 6 5 8 Radio Remote Control Button 1 blue activates Extinguishing Button 2 red activates Ignition Buttons 3 yellow 4 yellow decrease increase the...

Страница 24: ...on P2 To modify the blinking value push button P3 to increase or P4 to decrease To exit push button P1 6 6 1 Thermostats Room Thermostat Function Buffer Thermostat It allows to set the Room Thermostat...

Страница 25: ...D D ISA BLED TIME SE T D AY OFF B A N D ON BA N D DAY PROGRAMMING AROUND MIDNIGHT Set Hour of On for previous day to desired value Example 20 30 Set Hour of OFF for previous day at 23 59 Set Hour of O...

Страница 26: ...limited in the threshold P05 and P27 Code Description Min Max U 13kW 25kW C01 Auger TimeON Ignition 0 60 s 2 2 C02 Auger TimeON Stabilization 0 60 s 2 2 C03 Auger TimeON Power 1 P27 60 s 1 2 C04 Auger...

Страница 27: ...Power 1 Speed 0 230 Volt 100 120 300 2800 RPM 1100 1300 U04 Power 2 Speed 0 230 Volt 115 125 300 2800 RPM 1200 1400 U05 Power 3 Speed 0 230 Volt 125 145 300 2800 RPM 1250 1500 U06 Power 4 Speed 0 230...

Страница 28: ...ture Exhausting 5 900 C 250 270 Th09 Ignition Bypass Thermostat Exhausting 5 900 C 250 250 Th18 Antifreeze Thermostat Stove 5 10 C 5 5 Th19 Enable Pump Thermostat Stove 30 85 C 55 55 Ih19 Enable Pump...

Страница 29: ...U 13kW 25kW T01 Ignition Cleaning Time 0 900 s 20 20 T02 Ignition Igniter Resistance Pre heating Time 0 900 s 60 60 T03 Ignition Pre Load Time 0 900 s 40 60 T04 Ignition Fix Time 1 3600 s 300 300 T05...

Страница 30: ...ption Min Max U Def A01 P26 0 0 Reached the Room Thermostat the stove goes in Extinguishing 0 3 nr 2 1 Reached the Room Thermostat the stove goes in Modulation 2 Reached the Room Thermostat the stove...

Страница 31: ...ignition attempts 1 5 nr 1 P03 Work Combustion Powers number 1 5 nr 5 P09 Pellet Sensor configuration 0 1 nr 0 P20 Configuration of Pressure Boiler Water Sensor 0 2 nr 0 P26 Plumbing system management...

Страница 32: ...usting 5 900 C 45 Th38 Power 4 Exhausting 5 900 C 45 Th39 Power 5 Exhausting 5 900 C 45 Th40 Modulation Power Exhausting 5 900 C 45 Th43 Power 1 Exhausting 5 900 C 45 6 8 Functioning States 6 8 1 Off...

Страница 33: ...5 If Exhausting Temp Th09 goes in Normal I Ignition U01 II Ignition U10 I Ignition C01 II Ignition C10 ON If Exhaust Temp Th02 If Exhausting Temp Th06 goes in Stabilization Control after T05 If Exhaus...

Страница 34: ...01 Pushing the button ON OFF when the system is in Extinguishing Timer Controls Combustion Fan Auger Igniter T16 Control after T16 If Exhausting Temp Th01 Thermostat waits and continues extinguishing...

Страница 35: ...If Room Temperature Room Thermostat goes in Standby A07 2 If Input AUX open Buffer Temperature Buffer Thermostat and P26 1 T15 Control after T15 If Exhausting Temp Th08 Thermostat If Water Temp Th25 T...

Страница 36: ...p Th25 Thermostat starts Timer T15 Goes in Extinguishing with error Er05 A13 1 If for time T43 Water Temp Boiler Thermostat d23 goes in Standby 6 8 11 Standby Parameter Controls Combustion Fan Auger I...

Страница 37: ...ermostat starts Timer T13 U09 OFF OFF If Exhausting Temp Th01 Thermostat Wait T16 Final Cleaning If Exhausting Temp Th01 Thermostat starts Timer T16 Max Speed Control after T16 Goes in OFF without err...

Страница 38: ...ditions The Modem is connected to the Control Board s port RS232 with cables and connectors given it is supplied with a AC DC Power Supply unit Use a SIM card in the Modem enabled to the traffic GSM d...

Страница 39: ...h the return of the Supply Voltage the system evaluates the saved data and If the stove were ON and the Exhausting Temperature more than Th06 d01 the system goes in Recover Ignition Pushing the button...

Страница 40: ...ximum available Combustion Power Boiler Thermostat d08 Water Temperature Boiler Thermostat The Combustion Power decreases reaching the Boiler Thermostat Water Temperature Boiler Thermostat The system...

Страница 41: ...Fan Speed P25 0 Exhausting Fan without Encoder the speed is defined by the set voltage value Volt The Regulation Step is of 5 Volt P25 1 Exhausting Fan with Encoder the speed is defined by the set num...

Страница 42: ...Installer Service Manual BURNiT PM Comfort Plus 42 N 6 9 9 Pressure Sensor Configuration...

Страница 43: ...ing poor combustion and low temperature in exhaust gas tube If exhaust gas tube is layered with tar insulate well the outside of exhaust tube Tar deposition may cause fire It s mandatory at least once...

Страница 44: ...pection report for the actions performed Cleaning the outer surface of pellet stove Use soft cloth and neutral cleaning detergents Cleaning the door glass Door glass is self cleaned during stove opera...

Страница 45: ...er during stove operation immediately stop operation of stove and clean the pellet hopper and burner properly Refuel pellet hopper again If pellet hopper still has of lot of dust and sawdust replace t...

Страница 46: ...holes on both sides of pellet stove 3 Model 13kw Clean the soot through the manholes under the burner After cleaning close the system When using of low quality pellets it s recommend that cleaning be...

Страница 47: ...terial for recycling according to the local regulations and requirements At the end of life cycle of each product its components are due to be disposed of in conformity with regulatory prescriptions O...

Отзывы: