6.9.10. Pressure Sensor Configuration
Example:
P26=0
Th18= 5 °C
Th19= 50°C
Th21= 80°C
P26=1
Th18= 5 °C
Th19= 40 °C
Th21= 80 °C
Th47= 8 °C
7. Cleaning and maintenance
It's mandatory to clean regularly the pellet stove and the exhaust system. This
ensures efficient stove operation.
IMPORTANT! Do not use any acid-contain detergents or flammable substances
when cleaning the pellet stove and the exhaust system. May cause fire!
7.1.
Cleaning and maintenance of exhaust gas tube
TAR is liquid formed during poor combustion and low temperature in exhaust gas
tube. If exhaust gas tube is layered with tar, insulate well the outside of exhaust
tube. Tar deposition may cause fire. It`s mandatory at least once per heating season
inspection and cleaning of exhaust gas system.
ATTENTION! Inspect and clean exhaust gas system (chimney) before the first start
of pellet stove!
7.2. Cleaning and maintenance of the pellet stove.
Cleaning and maintenance of the pellet stove must be performed regularly.
Clean the stove outer surface, glass, rope on the door, ash container periodically.
Clean the pellet burner daily.
Clean the pellet hopper once per month.
It's mandatory to clean stove totally for burned pellet amount of 800 kg to 1000 kg or
once per year.