Installer / Service Manual BURNiT PM Comfort
Plus
18 –ЕN
PIN
FUNCTION
CHARACTERISTICS
1
N
Voltage Power Supply
230 Vac ± 10% 50/60 Hz
F1= Fuse T5,0 A
2
L
3
N
Combustion Fan
Triac Regulation 1A max
4
L
5
N
Pump
Triac Regulation 1A max
6
L
7
N
Igniter Resistance
Relè 3 A max
8
L
9
N
Auger Pellet Engine
Triac Regulation 1A max
10
L
11
Safety Thermostat Input
HV1
Contact ON/OFF Normally closed
To Bypass if not used
12
13
Safety Pressure Switch
Input HV2
Contact ON/OFF Normally closed
To Bypass if not used
14
15
Red +
Exhausting Temperature
Probe
Thermocouple K: 500 °C Max
16
Green -
17
Probe or Room Thermostat /
Buffer Probe
NTC 10K @25 °C: 80 °C Max
18
19
Stove (boiler) Temperature
Probe
NTC 10K @25 °C: 120 °C Max
20
21
+5V
Encoder Signal
Signal TTL 0 / 5 V
22
GND
23
SEG
24
AUX Input: Chrono/Room
Thermostat
Contact ON/OFF
25
26
GND
Pressure Water Sensor
Analog Signal
27
SEG
30
+5V
28
GND
Sensor Pellet level
Signal 0 / 5 V
29
SEG
31
+V
CN1
Connector to Keyboard
Flat Cable
RS23
Connector RS232
Connection to Modem/Computer
Содержание BURNiT PM Comfort 13 Plus
Страница 16: ...Installer Service Manual BURNiT PM Comfort Plus 16 N 6 2 Wiring controller Version 1 V1...
Страница 17: ...Installer Service Manual BURNiT PM Comfort Plus 17 N 6 3 Wiring controller Version 2 V2...
Страница 42: ...Installer Service Manual BURNiT PM Comfort Plus 42 N 6 9 9 Pressure Sensor Configuration...