background image

 

 
 

    

 

 

 

INSTRUCTION MANUAL

 

FOR INSTALLATION 

USE AND MAINTENANCE 

 

 

 

 

 

 

 

TYPE 

      RNO 200                     

MODEL 

 

SAVE THESE INSTRUCTIONS

 

Содержание RNO 200

Страница 1: ...1 INSTRUCTION MANUAL FOR INSTALLATION USE AND MAINTENANCE TYPE RNO 200 MODEL SAVE THESE INSTRUCTIONS ...

Страница 2: ...imney Systems p 7 INSTALLATION Initial advices p 17 Installation distances from flammable material p 18 OPERATION Lighting and Combustion p 19 COMBUSTIBLE p 22 SAFETY Air inlet p 23 Home fire safety p 24 Ceramic lining p 26 Advices on the Safety of Children and Adults p 26 ASSEMBLY SCHEMES p 28 MAINTENANCE p 31 WARRANTY p 32 ...

Страница 3: ...3 SCHEME WITH LEGENDA 0 31inches 1 18 inches 1 57 inches ...

Страница 4: ...alled on a roof lower than a higher nearby roof the distance must be more than 5 meters 16 50 ft FIG 4A The inner section of the chimney flue shall be uniform and without narrowings possibly round shaped with smooth walls and corners not any higher than 45 The section of the chimney flue must be bigger than the diameter of the stove smoke pipe 150mm 6 inches For our stoves we recommend a chimney f...

Страница 5: ...5 shall end with an airtight door accessible for cleaning This will avoid unpleasant smells bad draft and frequent cleaning of the stove FIG 2 A FIG 2 B FIG 2 C 16 40 ft ...

Страница 6: ...mney flue of rain and snow In very windy areas it is recommended to install an appropriate chimneypot It must be insulated like the chimney flue until its holes In case the brick chimney flue has an internal pipe this pipe shall continue until the holes in the chimneypot Avoid the output of two chimneys flues in the same chimneypot fig 2D If the chimneypot cannot be placed on the ridge of the roof...

Страница 7: ... Follow instructions provided by the manufacturer for manufactured thimbles for masonry chimney and factory built chimneys Instructions 1 Open inside wall at proper height for the chimney connector to entry the masonry chimney 2 Entry hole to masonry chimney must be lined with an 8 inch 203mm minimum diameter clay liner or equivalent secured with refractory mortar 3 Construct a 17 inch x 17 inch 4...

Страница 8: ...lid Pack Chimney with metal Supports as a Thimble NOTE In Canada when using a factory built chimney it must be safety listed Type UL103 HT 2100oF CLASS A or conforming to CAN ULC S629M STANDARD FOR 650oC FACTORY BUILT CHIMNEYS ...

Страница 9: ... to combustibles Factory built chimney connector vented Factory built chimney connector vented The listed connectors must conform to each other to ensure a proper fit and seal C Installing Chimney Components Single wall connector or stove pipe This must be at least 24 gauge mild steel or 26 gauge blue steel The sections must be attached to the appliance and to each other with the crimped male end ...

Страница 10: ...l FIGURE 3D WARNING Improper installation adjustment alteration service or maintenance can cause injury or property damage Refer to this information manual provided with the appliance For assistance or additional information consult a qualified installer service agency or your dealer ...

Страница 11: ...instructions for installation NOTICE In Canada when using a factory built chimney it must be safety listed Type UL103 HT 2100 F 1149 C CLASS A or conforming to CAN ULC S629 STANDARD FOR 650 C FACTORY BUILT CHIMNEYS FIGURE 3E Factory built exterior chimney WARNING Fire Risk Follow chimney connector Manufacturer s instructions for proper installation ONLY use connector within the room between applia...

Страница 12: ...TO KEEP INSULATION OR OTHER MATERIAL AWAY FROM VENT PIPE MAY CAUSE FIRE WARNING Fire Risk Inspection of chimney chimney must be in good condition meets minimum standard of NFPA 211 factory built chimney must be 7 8 180 200mm UL 103 HT WARNING ASPHYXIATION RISK DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVICING ANOTHER APPLIANCE DO NOT CONNECT TO ANY AIR DISTRIBUTION DUCT OR SYSTEM May allow flue...

Страница 13: ...r diameter than 6 8 inches 160 200 mm be relined the oversized flue can cause poor performance and contribute to the accumulation of creosote 3 Have the chimney cleaned before the appliance is installed and operated The following bullets list the more critical requirements for a properly constructed chimney WARNING Fire risk When lining air cooled factory built chimneys run chimney liner approved ...

Страница 14: ... the size of the flue should be checked to determine that it is not too large for the appliance The chimney should also be checked to ensure it meets the minimum standard of the National Fire Protection Association NFPA Standard 211 A chimney support package must be used when a connection is made through the ceiling to a factory built chimney An approved thimble and chimney support package are abs...

Страница 15: ...n drafts Consider the appliance location in order to avoid floor and ceiling attic joists and rafters Locate termination cap away from trees adjacent structures uneven roof lines and other obstructions Your local dealer is the expert in your geographic area and can usually make suggestions or discover solutions that will easily correct your flue problem NOTICE Chimney performance may vary Trees bu...

Страница 16: ...16 1 64 ft over the ridge reflux area 4 26 ft h min 4 ft 2 62 ft d 16 50 ft 1 64 ft 1 64 ft ...

Страница 17: ...allation must guarantee easy access to clean the stove the smoke pipes and the chimney flue as well Air extraction fans when installed in the same space or room with the stove can cause draft problems ALL LOCAL REGULATIONS MUST BE RESPECTED IN THE INSTALLATION OF THE STOVE Do not use the stove as an incinerator or in any other way different from the one it has been conceived for Do not use fuels d...

Страница 18: ... from rear flammable wall material 200 mm 8 inches Minimum distance from flammable floor 80 mm 3 inches Minimum distance from front flammable material 1000 mm 40 inches MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS inches NOTE All A C and F Dimensions are to the center diameter of flue collar INSTALLATION FULL VERTICAL SINGLE WALL PIPE A 18 B 8 C 18 D 8 E 8 F 18 G 44 H I J INSTALLATION HORIZONTAL WI...

Страница 19: ...n While lighting the stove both registers shall be totally opened This registers are placed in the base of the stove like in the following drawings The use will be as follows To light the stove air registers completely opened For a fast and powerful combustion primary air register half opened secondary air register opened For slow combustion primary air register opened secondary air register 1 3 o...

Страница 20: ... or otherwise locally dispersed they should be retained in the closed container until all cinders have thoroughly cooled By using dry and seasoned wood for lighting the stove it is possible to obtain a high flame and to immediately activate the draft in the chimney When the brazier is formed on the fireplace floor it is possible to insert larger logs always crossed for proper oxygenation When the ...

Страница 21: ...pot High wood consumption WARNING RISK OF BACKFIRE AND EXPLOSION NEVER USE GASOLINE GASOLINE TYPE LANTERN FUEL KEROSENE CHARCOAL LIGHTER FLUID OR SIMILAR LIQUIDS TO START OR FRESHEN UP A FIRE IN THIS HEATER KEEP ALL SUCH LIQUIDS WELL AWAY FROM THE HEATER WHILE IT IS IN USE DURING COMBUSTION THE FIREPLACE DOOR MUST REMAIN CLOSED Whenever you need to open the door to introduce wood in the fireplace ...

Страница 22: ... The resinous species eg Larch Spruce European species of Pine while providing a significant amount of heat during combustion have some drawbacks described below Have a low specific weight and therefore burn quickly Contain resin have a rather sooty combustion and therefore require more frequent chimneys and stove cleaning They produce hot particles They produce few embers It is recommended to bur...

Страница 23: ...entilation the minimum recommended section is 80 cm2 12 inches2 for devices with closed fireplace The air intake must be directly communicating with the room in which the stove is installed Avoid any obstruction and protect it with a grid as long as it does not reduce the minimum section The adjacent room cannot be used as a garage storage of combustible material or for activities with risk of fir...

Страница 24: ...place a protection made of incombustible material i e inox steel stone glass should be placed with a lateral extension of 203mm 8 inches and a frontal extension of 406mm 16 inches Under the chimney connector 2 inches 51 mm beyond each side FLOOR PROTECTION REQUIREMENTS Use of a floor protector listed to UL 1618 Type 1 ember floor protector or non combustible material Extend beneath appliance and t...

Страница 25: ...stalled in the room with the appliance 3 A conveniently located Class A fire extinguisher to contend with small fires resulting from burning embers 4 A practiced evacuation plan consisting of at least two escape routes 5 A plan to deal with a chimney fire as follows In the event of a chimney fire a Evacuate the house immediately b Notify fire department Negative pressure results from the imbalance...

Страница 26: ... carefully following the installation instructions provided in this manual ADVICE ON THE SAFETY OF CHILDREN AND ADULTS During the stove functioning the ceramic coating heats up progressively until 40 50 C to give heat to the environment It is very important to keep the children away from the stove in order to avoid touching the ceramic coating with the risk of burns In addition the ceramic glass a...

Страница 27: ...ss until it is cooled NEVER allow children to touch glass Keep children away CAREFULLY SUPERVISE children in same room as appliance Alert children and adults to hazards of high temperatures High temperatures may ignite clothing or other flammable materials Keep clothing furniture draperies and other flammable materials away ...

Страница 28: ...28 ASSEMBLY SCHEMES ...

Страница 29: ...29 ASSEMBLY SCHEMES ...

Страница 30: ...30 ASSEMBLY SCHEMES ...

Страница 31: ...flue of a slow burning fire As a result creosote residues accumulates in the flue lining When ignited this creosote makes an extremely hot fire The chimney connector and chimney should be inspected at least once every two months during the heating season to determine if a creosote buildup has occurred If creosote has accumulated it should be removed to reduce the risk of a chimney fire In normal c...

Страница 32: ...orized persons by modifications and substitutions of individual components by a poorly built and not suitable chimney flue This warranty does not extend to the refractory bricks inside the fireplace because their duration depends on how wood is loaded by the User The cost of repair or replacement of the goods shall be borne by the Seller The buyer agrees to make use of this warranty subject to rev...

Страница 33: ...LA CASTELLAMONTE di R Perino e S Neri Snc Via Casari 13 s n Tel e fax 0039 124 581690 0039 124 514149 10081 Castellamonte TO Italy www lacastellamonte it www stackstoves com e mail info lacastellamonte it ...

Отзывы: