Chapter 4
Chassis Components
4-9
4. Set the fan down into the bracket.
See
FIGURE 4-10
.
FIGURE 4-10
Installing Fans 0-3
5. Connect the fan cable to its respective connector.
Use the following table.
See
FIGURE 4-10
.
Note –
Connect the SAS cables to
J7
of the SAS IF board after connecting the fan
cable from
F3.
6. Repeat
Step 3
to
Step 5
for each fan being installed.
7. Determine your next steps:
■
If you were directed here by another procedure, return to that procedure.
■
Otherwise, install the air duct and top cover, install the server into the rack,
power on the server, and verify the installation.
■
See
Section 5.1, “Installing the Top Cover” on page 5-1
.
■
See
Section 5.3, “Installing the Server Into the Rack” on page 5-4
.
■
See
Section 5.4, “Powering On the Server” on page 5-6
.
TABLE 4-2
Fans 0-3 and Their Connectors
Fan
Connector
Fan0
J1
, adapter board
Fan1
J2
, adapter board
Fan2
F2
, system board
Fan3
F3
, system board