Netra 210 Server Service Manual • March 2006
4.2
Replacing the Power Supply
4.2.1
Removing the Power Supply
1. Power off the server, remove the server from the rack, and remove the top cover
and airduct.
■
See
Section 1.3, “Powering Off the Server” on page 1-3
.
■
See
Section 1.4, “Removing the Server From the Rack” on page 1-4
.
■
See
Section 1.6, “Removing the Top Cover” on page 1-7
.
2. Locate the power supply.
The power supply is located at the right rear of the chassis.
3. Remove fan 4 and 5.
See
Section 4.4.1, “Removing Fans 4 and 5” on page 4-10
.
4. Lift the SAS cables out of the clamps on the side of the power supply.
See
FIGURE 4-1
.
FIGURE 4-1
Lifting the SAS Cables Out of the Clamps
5. Disconnect the power supply cables from the connectors in this order:
■
P2
, on the system board
■
P3
, on the system board
■
P1
, on the system board
■
J501
, from the SAS IF assembly
See
FIGURE 4-2
.