Section 5.5, “Verifying the Installation” on page 5-7
.
4.4
Replacing Fans 4 and 5
4.4.1
Removing Fans 4 and 5
1. Power off the server, remove the server from the rack, and remove the top cover.
■
See
Section 1.3, “Powering Off the Server” on page 1-3
.
■
See
Section 1.4, “Removing the Server From the Rack” on page 1-4
.
■
See
Section 1.6, “Removing the Top Cover” on page 1-7
.
Note –
It is not necessary to remove the air duct.
2. Locate the fans.
Fans 4 and 5 are located between the SAS IF assembly and the power supply at the
right front of the chassis.
3. Lift both fans up and out of the bracket.
See
FIGURE 4-11
.
FIGURE 4-11
Removing Fans 4 and 5
4. Disconnect the fan cable of the fan to be removed from the power supply:
■
Fan 4 -
J7