4-8
Netra 210 Server Service Manual • March 2006
FIGURE 4-9
Removing Fans 0-3
Note –
Remove the SAS cables from
J7
of the SAS IF board before removing the fan
cable from
F3.
4. Lift the fan up and out of its bracket.
See
FIGURE 4-9
.
5. Set the fan aside on an antistatic mat.
6. Repeat
Step 3
to
Step 5
for each fan to be removed.
Caution –
Do not power on the server without the fans installed.
7. Determine your next steps:
■
If you were directed here by another procedure, return to that procedure.
■
Otherwise, replace the fans.
Go to
Step 3
of
Section 4.3.2, “Installing Fans 0-3” on page 4-8
.
4.3.2
Installing Fans 0-3
1. Remove the server from the rack and remove the top cover.
■
See
Section 1.4, “Removing the Server From the Rack” on page 1-4
.
■
See
Section 1.6, “Removing the Top Cover” on page 1-7
.
2. Locate where the fan installs.
Fans 0-3 install at the center front of the chassis.
3. Remove the replacement fan from its shipping container and antistatic packaging.