B-4
Netra 210 Server Service Manual • March 2006
Caution –
You must use a shielded Ethernet cable to maintain your server’s NEBS
compliance. The cable’s shield must be grounded at both ends.
FIGURE B-3
shows the pin numbering of the serial management port, and
TABLE B-5
describes the pin signals.
FIGURE B-3
Serial Management Port Pin Numbering
If you need to connect to the SERIAL MGT port using a cable with either a DB-9 or
a DB-25 connector, use a supplied adapter to perform the crossovers given for each
connector. The supplied RJ-45 to DB-9 and RJ-45 to DB-25 adapters are wired as
described in
TABLE B-6
and
TABLE B-7
.
B.3.1.1
RJ-45 to DB-9 Adapter Crossovers
TABLE B-5
Serial Management RJ-45 Connector Signals
Pin
Signal Description
Pin
Signal Description
1
Request to Send
5
Ground
2
Data Terminal Ready
6
Receive Data
3
Transmit Data
7
Data Set Ready
4
Ground
8
Clear to Send
TABLE B-6
RJ-45 to DB-9 Adapter Crossovers
Serial Port (RJ-45 Connector)
DB-9 Adapter
Pin
Signal Description
Pin
Signal Description
1
RTS
8
CTS
2
DTR
6
DSR
3
TXD
2
RXD
4
Signal Ground
5
Signal Ground
1
8
Содержание Netra 210
Страница 12: ...xii Netra 210 Server Service Manual March 2006...
Страница 28: ...1 12 Netra 210 Server Service Manual March 2006...
Страница 72: ...3 32 Netra 210 Server Service Manual March 2006...
Страница 104: ...5 8 Netra 210 Server Service Manual March 2006...
Страница 108: ...A 4 Netra 210 Server Service Manual March 2006...
Страница 118: ...B 10 Netra 210 Server Service Manual March 2006...
Страница 122: ...Index 4 Netra 210 Server Service Manual March 2006...