Chapter 3
System Board Components
3-13
FIGURE 3-18
Removing the SAS Board
9. Set the SAS board aside on an antistatic mat.
Caution –
Do not power on the server without the SAS board installed.
10. Determine your next steps:
■
If you were directed here by another procedure, return to that procedure.
■
Otherwise, replace the SAS board.
Go to
Step 4
of
Section 3.4.2, “Installing the SAS Board” on page 3-13
.
3.4.2
Installing the SAS Board
1. Power off the server, remove the server from the rack, and remove the top cover
and airduct.
■
See
Section 1.3, “Powering Off the Server” on page 1-3
.
■
See
Section 1.4, “Removing the Server From the Rack” on page 1-4
.
■
See
Section 1.6, “Removing the Top Cover” on page 1-7
.
2. If installed, remove the PCI card.
See
Section 3.3.1, “Removing the PCI Card” on page 3-5
.
3. Locate where the SAS board installs.
The SAS board installs under the PCI card at the left rear of the system board.
4. Remove the replacement SAS board from its shipping container and antistatic
packaging.
5. Align the holes of the SAS board over the plastic and metal standoffs.