2-6
Netra 210 Server Service Manual • March 2006
a. Determine the
Ap_Id
for the hard drive installed. As superuser in a terminal
window, type:
b. Search the
Type
column for the first occurrence of the word,
disk
.
This is the entry for
HDD0
. In this example, the respective
Ap_Id
for
HDD0
is
c1::dsk/c1t0d0
.
The entry immediately following is for
HDD1
, or
c1::dsk/c1t1d0
.
c. Configure the installed hard drive.
■
To configure
HDD0
, type:
■
To configure
HDD1
, type:
■
Otherwise, close the bezel
, power on the server, and verify the installation
.
■
See
Section 5.2, “Closing the Bezel” on page 5-3
.
■
See
Section 5.4, “Powering On the Server” on page 5-6
.
■
See
Section 5.5, “Verifying the Installation” on page 5-7
# cfgadm -al
Ap_Id
Type
Receptacle
Occupant
Condition
c0
scsi-bus
connected
configured
unknown
c0::dsk/c0t0d0
CD-ROM
connected
configured
unknown
c1
scsi-bus
connected
configured
unknown
c1::dsk/c1t0d0
disk
connected
unconfigured unknown
c1::dsk/c1t1d0
disk
connected
unconfigured unknown
c2
scsi-bus
connected
unconfigured unknown
c3
scsi-bus
connected
unconfigured unknown
c4
fc-private
connected
configured
unknown
c4::216000c0ff883cc4
disk
connected
configured
unknown
c5
fc
connected
unconfigured unknown
usb0/1 unknown empty unconfigured ok
usb0/2 unknown empty unconfigured ok
# cfgadm -c configure c1::dsk/c1t0d0
# cfgadm -c configure c1::dsk/c1t1d0
Содержание Netra 210
Страница 12: ...xii Netra 210 Server Service Manual March 2006...
Страница 28: ...1 12 Netra 210 Server Service Manual March 2006...
Страница 72: ...3 32 Netra 210 Server Service Manual March 2006...
Страница 104: ...5 8 Netra 210 Server Service Manual March 2006...
Страница 108: ...A 4 Netra 210 Server Service Manual March 2006...
Страница 118: ...B 10 Netra 210 Server Service Manual March 2006...
Страница 122: ...Index 4 Netra 210 Server Service Manual March 2006...