SLM MANUAL
7
118073-001 Rev C
Chapter 3
O
PERATING
I
NSTRUCTIONS
3.1 Operation
WARNING
THIS EQUIPMENT GENERATES
DANGEROUS VOLTAGES THAT MAY BE
FATAL. PROPER GROUNDING OF ALL HIGH
VOLTAGE EQUIPMENT IS ESSENTIAL.
IMPORTANT:
Before connecting the power supply to the
AC line, follow this step-by-step procedure.
Do not connect the power supply to the AC
line until Step F is reached.
Failure to follow these procedures may void
the warranty.
A)
Insure that the high voltage cable is properly
installed and terminated to the load. Insure that all
circuits connected to the high voltage output are safely
interlocked against accidental contact. Insure external
load is discharged.
B)
Check the input voltage rating on the serial
nameplate of the supply and make certain that this is the
rating of the available power source
C)
PROPER GROUNDING TECHNIQUE:
The
chassis of high voltage power supplies must be grounded,
preferably to a water system ground using copper pipe or
other earth ground. A ground stud is provided on the front
panel. See Figure 3.1 for a typical operating setup. The
return line from the load should be connected to the
power supply chassis. Using a separate external ground
at the load is not recommended. An IEC 320 connector is
provided for connection to the line voltage source. A
standard line cord is also provided.
D)
Hook-up:
Connect control and monitoring
connections as described in this manual.
E)
For initial turn-on, program the voltage and
current for zero output. Connect the enable/disable signal
to disable.
F)
The input power cable may now be connected to
the AC power line.
G)
Enable the power supply via the enable/disable
hardware based, dry contact closure.
H)
Slowly program the output voltage and current
to desired level. Monitor the output voltage and current
via the monitoring test points. Note equipment operation
is normal, i.e. load is behaving as predicted.
I)
To turn high voltage off, use the enable/disable
signal. If equipment is to be kept off for extended
periods, disconnect power supply from line voltage
source.
WARNING
AFTER TURNOFF, DO NOT HANDLE THE LOAD
UNTIL THE CAPACITANCE HAS BEEN
DISCHARGED!
LOAD CAPACITANCE MAY BE DISCHARGED BY
SHORTING TO GROUND.
WARNING
THE VOLTAGE MONITOR ON THE POWER
SUPPLY FRONT PANEL DOES NOT READ THE
OUTPUT VOLTAGE WHEN THE POWER IS
TURNED OFF, EVEN IF A CHARGE STILL
EXISTS ON THE LOAD.
CAUTION
ALWAYS OPERATE THE UNIT WITH THE COVER
ON. DO NOT ATTEMPT TO ACCESS OR REPAIR
ANY INTERNAL CIRCUITS. DANGEROUS AND
LETHAL VOLTAGES ARE GENERATED INSIDE
THE MODULE.
Содержание SLM SERIES
Страница 15: ...SLM MANUAL 6 118073 001 Rev C Figure 2 2 Unit Dimensions 1200W ...
Страница 19: ...SLM MANUAL 10 118073 001 Rev C Figure 3 3 Local Programming via External Voltage Source ...
Страница 20: ...SLM MANUAL 11 118073 001 Rev C Figure 3 4 Remote Monitoring ...
Страница 40: ...Figure 9 Web Page 1 Contact Information 118080 001 REV A Page 13 of 95 ...
Страница 46: ...4 2 2 9 About Displays version information and model number Figure 15 About 118080 001 REV A Page 19 of 95 ...
Страница 98: ...Request Faults 68 20 ASCII 118080 001 REV A Page 71 of 95 ...