![Spellman SLM SERIES Скачать руководство пользователя страница 102](http://html.mh-extra.com/html/spellman/slm-series/slm-series_instruction-manual_1346474102.webp)
6.6.4 Request Status
Description:
The host requests that the firmware sends the power supply status.
Direction:
Host to supply
Syntax:
<STX><22><,><CSUM><ETX>
Example:
<STX>22,<CSUM><ETX>
Response:
<STX><22><,><ARG1><,><ARG2><,><ARG3><,><ARG4><,><ARG5><,
><ARG6><,><ARG7><,><ARG8><,><CSUM><ETX>
Where:
<ARG1> 1 = HvOn, 0 = HvOff
<ARG2> 1 = Interlock 1 Open, 0 = Interlock 1 Closed
<ARG3> 1 = Fault Condition, 0 = No Fault
<ARG4> 1 = Remote Mode, 0 = Local Mode
<ARG5> 1 = I Mode on, 0 = = I Mode off
<ARG6> 1 = ROV Enabled, 0 = ROV Disabled
<ARG7> 1 = AOL Enabled, 0 = AOL Disabled
<ARG8> 1 = Watchdog Enabled, 0 = Watchdog Disabled
Example:
<STX>22,1,1,0,0,0,0,0,0,<CSUM><ETX>
118080-001 REV A
Page 75 of 95