6.6.12 Request kV Monitor
Description:
The host requests that the firmware report kV monitor.
Direction:
Host to supply
Syntax:
<STX><60><,><CSUM><ETX>
Response:
<STX><60><,><ARG><,><CSUM><ETX>
Where:
<ARG>=0-4095 in ASCII format representing unscaled value.
Example:
<STX>60,4095,<CSUM><ETX>