5.5.18 Turn HV on/off
Description:
The host requests that the firmware turn high voltage on or high voltage
off.
Direction:
Host to supply
Syntax:
<STX><98><,><ARG><,><ETX>
Where:
<ARG> 1 = HV on, 0 = HV off in ASCII format
Example:
<STX>98,1,<ETX>
Response:
<STX><98><,><$><,><ETX>
<STX><98><,><ARG><,><ETX>
where <ARG> = error code
Error Codes TBD,
1 = out of range