5.5.20 Program RS-232 Baud rate
Description:
The host requests that the firmware change the Baud rate for RS-232.
Direction:
Host to supply
Syntax:
<STX><07><,><ARG><,><ETX>
Where:
<ARG> 1 = 9.6k in ASCII format
<ARG> 2 = 19.2k in ASCII format
<ARG> 3 = 38.4k in ASCII format
<ARG> 4 = 57.6k in ASCII format
<ARG> 5 = 15.2k in ASCII format
Example:
<STX>07,1,<ETX>
Response:
<STX><07><,><$><,><ETX>
<STX><07><,><ARG><,><ETX>
where <ARG> = error code
Error Codes TBD,
1 = out of range
118080-001 REV A