6.6.15 Request Faults
Description:
The host requests that the firmware report Faults.
Direction:
Host to supply
Syntax:
<STX><68><,><CSUM><ETX>
Response:
<STX><68><,><ARG1><,><ARG2><,><ARG3><,><ARG4><,><ARG5><,
><ARG6><><,><ARG7><,><CSUM><ETX>
Where:
<ARGx> 1 = Fault, 0 = No Fault in ASCII format
ARG1 = ARC
ARG2 = Over Temperature
ARG3 = Over Voltage
ARG4 = Under Voltage
ARG5 = Over Current
ARG6 = Under Current
ARG7 = Wathdog
Example:
<STX>67,0,0,0,0,1,0,0,<CSUM><ETX>