![Spellman SLM SERIES Скачать руководство пользователя страница 79](http://html.mh-extra.com/html/spellman/slm-series/slm-series_instruction-manual_1346474079.webp)
5.5.12 Program Network Settings
Description:
The host requests that the firmware programs the network settings and
then reboots.
Application:
ARG 1
ARG2
ARG3
ARG4
ARG5
Function
Device
Name
Remote
Address
Remote
Port
Subnet
Mask
MAC
Address
Direction:
Host to supply
Syntax:
<STX><51><,><ARG1><,><ARG2><,><ARG3><,><ARG4><,>
<ARG5><,><ARG6><,><ETX>
Arguments:
Device Name is limited to 20 characters or less. Remote address is a ip
address in dotted notation. Remote port is a decimal number. Subnet
Mask and Default Gateway are also dotted notation and MAC address is
in MAC Address notation.
ARG1: Device Name
1 character minimum, up to 20 maximum
ARG2: IP Address
<nnn><.><nnn><.><nnn><.><nnn>, where
<nnn> represents a number from 0 to 255.
ARG3: Remote Port
5001 or from 49152 to 65535.
ARG4: Subnet Mask
<xxx><.><xxx><.><xxx><.><xxx>, where
<xxx> represents a number from 0 to 255.
ARG5: MACAddress
<zzz><:><zzz><:><zzz><:><zzz><:><zzz>
<:><zzz> , where <zzz> represents a number
from 0 to 255.
Example:
<STX>51,Spellman2.0,32.78.110.37,1026,255.0.0.0,0:100:33:1:32:84,<E
TX>
Response:
None, as Embedded server reboots with new settings.
118080-001 REV A
Page 52 of 95
Содержание SLM SERIES
Страница 15: ...SLM MANUAL 6 118073 001 Rev C Figure 2 2 Unit Dimensions 1200W ...
Страница 19: ...SLM MANUAL 10 118073 001 Rev C Figure 3 3 Local Programming via External Voltage Source ...
Страница 20: ...SLM MANUAL 11 118073 001 Rev C Figure 3 4 Remote Monitoring ...
Страница 40: ...Figure 9 Web Page 1 Contact Information 118080 001 REV A Page 13 of 95 ...
Страница 46: ...4 2 2 9 About Displays version information and model number Figure 15 About 118080 001 REV A Page 19 of 95 ...
Страница 98: ...Request Faults 68 20 ASCII 118080 001 REV A Page 71 of 95 ...