Chapter 4
Maintenance
4-12
Chapter 4
Maintenance
Low-grade error and serious error warnings
Immediate Warnings
Message
FC Board:::System Serious Error Occured (BoardID =
XXXXXXXX)
Please Check Error Log for Board.
RAID:::LogicalDrive Serious Error Occurred (B_ID =
XXXXXXXX, R_ID = XXXXXXXX.
Please Check Error LOG for RAID.
HDD:::HDD Serious Error Occurred (B_ID = XXXXXXXX,
R_ID = XXXXXXXX, HDD node name = XXXXXXXX.
Please Check Error LOG for HDD.
FC Board:::Low-grade System Error Occured (BoardID =
XXXXXXXX)
Please Check Error Log for Board.
RAID:::Low-grade LogicalDrive Error Occurred (B_ID =
XXXXXXXX, R_ID = XXXXXXXX.
Please Check Error LOG for RAID.
HDD:::Low-grade HDD Error Occurred (B_ID = XXXXXXXX,
R_ID = XXXXXXXX, HDD node name = XXXXXXXX.
Please Check Error LOG for HDD.
Description
A serious error occurred on a Fibre Channel Interface Board.
A serious error occurred on a RAID.
A serious error occurred on a hard disk.
A low-grade error occurred on a Fibre Channel Interface
Board.
A low-grade error occurred on a RAID.
A low-grade error occurred on a hard disk.
4-1
Fibre Channel Storage Unit Maintenance
Message
Failed creating RAID. Some disks become ‘Used Disk’.
RAID (ID n) may be made by older version. So you cannot
use Recover Error function (Warning).
Please open a Maintenance Menu on DiskUtility and perform
Verify System Area.
RAID (ID n) may be made by older version. Stop I/O now!
If you continue I/O, this drive may be broken (Serious).
Please open a Maintenance Menu on DiskUtility and perform
Verify System Area.
Management Table of RAID (ID n) may be broken. So you
cannot use Recover Error function.
Please open a Maintenance Menu on DiskUtility and perform
Verify System Area.
Management Table of RAID (ID n) is full.
There is a possibility that the error information on Disk may be
extinguished (Warning).
Please open a Maintenance Menu on DiskUtility and perform
Repair Defects.
Management Table of RAID (ID n) is full. Stop I/O now!
If you continue I/O, this drive may be broken (Serious).
Please open a Maintenance Menu on DiskUtility and perform
Repair Defects.
Disk, node name: XXXXXXXX, is disconnected.
Please check the connection.
Description/Steps to take
One or more of the disks making up a RAID could not be
confirmed, and their status is now Used. This can occur
because of FC cable or disk connection mistakes, or because
of RAID data discrepancies after disks were moved.
To release the Used status and restore the disks to Free
status, execute Release Used Drive with the Disk Utility.
RAID ID n was constructed with an older version.
You need to execute Verify System Area on the Maintenance
Menu of the Disk Utility.
RAID ID n was constructed with an older version.
You need to execute Verify System Area on the Maintenance
Menu of the Disk Utility. Failure to do so could result in the
loss of data.
The management table of RAID ID n may be broken. You
need to execute Verify System Area on the Maintenance
Menu of the Disk Utility.
The management table of RAID ID n is full.
You need to execute Repair Defects on the Maintenance
Menu of the Disk Utility.
The management table of RAID ID n is full.
You need to execute Repair Defects on the Maintenance
Menu of the Disk Utility. Failure to do so could result in the
loss of data.
A disk is disconnected.
Check that the disk and FC cable are securely connected. If
this message appears even when they are properly
connected, there may be a broken line in the FC cable.
Replace the cable.
(Continued)