Chapter 2: Intended Use and General Information
Veterinary 3 Parameter Advisor
®
Operation Manual
2-1
Intended Use
This vital signs monitor is intended to be used in special procedure labs and other areas of a veterinary hospital
or clinic where veterinary monitoring systems are needed. The monitor package includes 3-lead or 5-lead
electrocardiography (ECG), non-invasive blood pressure (NIBP), and pulse oximetry (SpO
2
).
The device permits patient monitoring with adjustable alarm limits as well as visible and audible alarm signals.
The monitor provides fast, reliable measurements for patients ranging from cats to horses when using the
appropriate SurgiVet
®
accessories. The monitor is not intended for home use. The monitor is not intended to be
an apnea monitor. It was not designed or validated for use as an apnea monitor.
WARNING! This monitor is not for apnea detection. The monitor has not been tested or validated for use
in apnea detection.
WARNING! This monitor is not for home use.
WARNING! Verify proper operating mode before attaching patient. See
Select the Patient Type
in
Chapter
4
:
Setting Up the Monitor.
Measurement Capabilities
Heart/Pulse Rate
Heart/pulse rate is measured with the ECG, oximetry, and non-invasive blood pressure (NIBP) parameters. The
measured values can be continuously displayed in the ECG and SPO
2
parameter boxes. Heart/pulse rate can also
be displayed in the NIBP HISTORY, found in the TRENDS menu. You can choose the source (AUTO, ECG, or SPO
2
)
of the heart/pulse rate displayed in the ECG parameter box. If you choose AUTO, the monitor will determine the
best source depending on the quality of available data and selected source priority. See
Choose the Heart Rate
Source
in
Chapter 7: ECG
for detailed information regarding the source of the heart/pulse rate displayed in the
ECG parameter box.
Electrocardiography (ECG)
The monitor provides continuous three-lead or five-lead ECG processing, with standard lead selections, and
filtering from electrocautery discharge. The ECG measured value (HR) and primary lead selection are displayed in
the ECG parameter box, and an ECG waveform is continuously displayed.
Oximetry
The oximetry parameter provides the continuous non-invasive monitoring of oxygen saturation (%SpO
2
) in the
blood and peripheral pulse rate (PPR). The measured values for oximetry (%SpO
2
and PPR) and a pulse strength
bar graph are displayed in the SPO
2
parameter box. A plethysmogram, or oxygen saturation waveform, can be
continuously displayed. A variety of disposable and reusable sensors is available for monitoring patients.
Non-invasive Blood Pressure (NIBP)
The non-invasive blood pressure (NIBP) parameter provides systolic, diastolic, and mean arterial blood pressure
values, and heart rate. The measured values for non-invasive blood pressure (SYS, DIA, and MAP) are displayed in
the NIBP parameter box. NIBP measurements can be made in automatic, manual, or STAT modes.
Chapter 2: Intended Use and General Information
Содержание SurgiVet Advisor WWV9230
Страница 2: ......
Страница 10: ...Table of Contents viii Veterinary 3 Parameter Advisor Operation Manual This page is intentionally left blank ...
Страница 68: ...Chapter 7 ECG 7 14 Veterinary 3 Parameter Advisor Operation Manual This page is intentionally left blank ...
Страница 80: ...Chapter 8 Oximetry 8 12 Veterinary 3 Parameter Advisor Operation Manual This page is intentionally left blank ...
Страница 106: ...Chapter 12 Service Menu 12 8 Veterinary 3 Parameter Advisor Operation Manual This page is intentionally left blank ...
Страница 120: ...Appendix D Revision History D 2 Veterinary 3 Parameter Advisor Operation Manual This page is intentionally left blank ...
Страница 121: ......