Introduction
8
40-5648-51B
Symbols
The following is a list of symbols which may appear on
the pump (or on it’s labeling or accessories), as well as
certain technical terms, along with an explanation of
what they mean.
>
Serial number
g
Attention, See instructions for use
J
Type CF equipment (protection from elec
-
tric shock)
K
Equipment in which protection against
electric shock relies on double or reinforced
insulation instead of basic insulation. Acces
-
sible metal components of pump enclosure
use this higher level of insulation instead
of safety grounding.
Medfusion™ 3500BC
pumps:
The earth ground of the power cord
serves the purpose of providing a “function
-
al earth” return for electromagnetic energy.
J
Date of manufacture
6
CAUTION: Federal (USA) law restricts this
device to sale by or on the order of a physi
-
cian.
<
Catalog number
Z
Collect Separately
9
Latex free
7
Do not reuse
8
Use by
@
Authorized representative in the European
Community
Australian representative
5
Indicates the product was designed and
manufactured in accordance with applicable
standards/guidelines and may be sold in the
EU (European Union).
ó
UL Mark for Canada and the United States.
Indicates the product was manufactured in
accordance with the requirements of UL
(Underwriter’s Laboratory).
P
Temperature limitation
_
Humidity limitation
i
Atmospheric pressure limitation
Ü
Pins of connectors and other areas identi
-
fied with this
ESD Warning symbol should
not be touched. Connections should only
be made when ESD precautionary measures
are used.
Ö
External DC jack connection. Tip (negative
sign) is for power ground and ring (positive
sign) is for positive power connection. (See
warning that follows.)
Ñ
Symbol for infrared serial communications
port on pump.
V ~
Operating voltage range for alternating cur
-
rent (i.e. AC or mains) power source
F2
Medfusion™ 3500BC pumps:
The designa-
tion “F2” indicated on the label, which is
located on the AC input module connec-
tor assembly for the pump, is indicating a
non-replaceable fuse that is part of the input
module assembly. The fuse is located on the
neutral side of the AC line.
Medfusion™ 3500BC pumps:
The “ground”
symbol indicated on the label, which is
located on the AC input module connector
assembly for the pump, is indicating that
the earth ground connection is providing a
functional ground and not a safety ground.
IPX3 Equipment that is ingress protected from
fluid spraying at vertical angle from above,
and from angles to 60° on either side of
vertical
Infusion Class 4 An infusion pump that combines
the functions of continuous infu
-
sion flow, intermittent flow, and
discrete bolus delivery
Infusion Class 5 An infusion pump that functions
as a profile pump, providing a
programmed sequence of delivery
rates
Содержание Medfusion 3000 Series
Страница 1: ...s Medfusion 3000 Series Technical Service Manual ...
Страница 2: ...Table of Contents ii 40 5648 51B ...
Страница 20: ...Introduction 14 40 5648 51B ...
Страница 32: ...Scheduled Maintenance 26 40 5648 51B ...
Страница 80: ...Troubleshooting 74 40 5648 51B ...
Страница 116: ...Calibration Adjustment 110 40 5648 51B ...
Страница 158: ...Assembly Drawings Parts Lists 152 40 5648 51B Medfusion 3000 series main pump assembly See Note 1 ...
Страница 160: ...Assembly Drawings Parts Lists 154 40 5648 51B Case bottom assembly Medfusion 3500BC ...
Страница 162: ...Assembly Drawings Parts Lists 156 40 5648 51B Case top assembly w plunger ...
Страница 164: ...Assembly Drawings Parts Lists 158 40 5648 51B Case top assembly without plunger ...
Страница 167: ...Assembly Drawings Parts Lists 161 40 5648 51B Barrel clamp assembly GREASE SILICONE III SOLDER NO CLEAN ...
Страница 172: ...Assembly Drawings Parts Lists 166 40 5648 51B Accessories parts list Poleclamp assembly ...
Страница 182: ...Index 176 40 5648 51B ...
Страница 183: ......