12.1 Timer operation
The interval and pump cycle are time-
dependent.
The lubrication cycle is controlled by the pre-
set, time-dependent values for PAUSE and
CONTACT.
PAUSE: Values in hours
CONTACT: Values in minutes
Set
tPA
and
tCO
in programming
mode.
12. KFGS operating modes
12.2 Counter operation
The interval depends on the number of pulses;
the pump cycle time is time-dependent.
An external pulse generator must be attached
as described in Chapter 4 in the assembly
instructions.
PAUSE: Values in pulses
CONTACT: Values in minutes
A switch opens and closes based on machine
movements, revolutions, etc.
A lubrication is triggered once the set number
of pulses (
cPA
) is reached.
Set
cPA
und
tCO
in programming
mode.
12.3 No system monitoring
In this operating mode, the lubrication cycle
is controlled solely by the pre-set values for
PAUSE and CONTACT.
Monitoring must be switched off.
COP
=
OFF
System malfunctions are
not automatically detected or displayed.
12.4 With system monitoring
In this operating mode, system functions are
additionally monitored using external switches.
The following can be monitored:
Fill level in the lubricant reservoir
Function of progressive feeder using a
piston detector
Function of single-line system using a
pressure switch
Operational malfunctions are automati-
cally detected and displayed. Monitoring
is switched on.
COP
=
CS
or
PS.
12. KFGS operating modes
K
F
G
S