11.3 Conigure system monitoring
Configure system monitoring
Step
Key
Display
1
Display flashes
(000
=
factory setting)
Press for more than 2 s
2
Automatic display of first
parameter: "pause in timer operation"
Press briefly
"PAUSE" LED flashes
(confirm code)
3
Beginning of monitoring settings
is displayed
Press until:
4
System monitoring switched off
(factory setting)
Press briefly
5
Press either until
or
Monitoring via piston
Monitoring via Pressure
detector "CS" LED flashes
switch "PS" LED flashes
6
Press briefly
Confirm new setting
7
New settings are written to memory,
Press for more than 2 s
the values are activated and
the display clears
System monitoring can be changed to activate
or deactivate the monitoring functions for
lubrication.
When system monitoring is active, you can se-
lect monitoring via piston detector on progres-
sive systems or monitoring via pressure switch
on single-line systems.