![SKF KFG Скачать руководство пользователя страница 52](http://html1.mh-extra.com/html/skf/kfg/kfg_assembly-instructions-manual_1287056052.webp)
Page 52
EN
5. Design
5.3 KFG pump units
Pump units of the KFG series are reservoir
pump units without an integrated control unit.
Pumps in the KFG series have different reser-
voir designs and reservoir capacities (2 kg,
6 kg and 10 kg) depending on their ield of
application.
Fill level switches with one to three switching
points can be attached to the cover to moni-
tor the pump ill level. The pump is available in
various voltage designs.
The ill level switch in the pump housing is
optionally available with signal smoothing. The
output signal only communicates the following:
Reservoir full (illed)
Reservoir empty.
5.4 KFGS pump units
Pump units of the KFGS series are reservoir
pump units with an integrated control unit.
Parameters for interval times (timer), interval
pulses (counter) and pump cycle times (con-
tact) can be entered through the control panel.
A piston detector is used to monitor the feed-
ing operation on progressive systems; a pres-
sure switch is used for single-line systems.
The KFGS pump is available in the same
reservoir designs, reservoir capacities and
voltage designs as the KFG series.
The ill level of pump units of the KFG/KFGS/
KFGC (CAN-Bus) series is monitored using the
ill level switches mentioned in the assembly
instructions (Chapter 4). The selection of ill
level switches depends on the particular series,
reservoir design and user application. The
selection of ill level switches is based on the
lubricant used, which then determines whether
the switches are installed in the pump housing
or reservoir cover.