4.5.4.1 Pressure relief valve with integrated
pressure regulating valve
(for single-line systems with VR distributors)
Plug-in connection per DIN EN 17530-803
200b
ar
P2
A
T
P1
Hydraulic block diagram
Electrical block diagram
Connector pin assignment
PIN
Description
1
(Current) Supply
voltage
potential
2
Ground
3
PE
Technical data
Pressure relief valve 24 VDC
Input voltage . . . . . . . . . . . . . 24 VDC
Rated output . . . . . . . . . . . . . 26 W
Rated current . . . . . . . . . . . . 1.2 A
ON-time . . . . . . . . . . . . . . . . 100%
Protection class . . . . . . . . . . . IP65
pressure regulating valve
Set pressure . . . . . . . . . . . . .200 bar
Plug-in connection per DIN EN 175301803
Pressure relief valve 230 VAC
Input voltage . . . . . . . . . . . . . 230 VAC
Coil voltage . . . . . . . . . . . . . . . 205 VDC
Rated output . . . . . . . . . . . . . 26 W
Rated current . . . . . . . . . . . . 0.13 A
ON-time . . . . . . . . . . . . . . . . 100% at 35 °C
pressure regulating valve
Set pressure . . . . . . . . . . . . .200 bar
Protection class . . . . . . . . . . . IP65
Plug-in connection per DIN EN 17530-803
Note
When VKR distributors are used, a
max. set pressure of 130 bar for the pressure
regulating valve must not be exceeded.