4. Assembly
4.1 General information
Pump units of the KFG, KFGS and KFGC (CAN
bus) series are an integral component of cen-
tralized lubrication systems used in machines
and systems.
They deliver greases up to NLGI Grade 2. The
pump units differ in terms of lubricant reser-
voir capacity, lubricant filling, control and func-
tion monitoring. The installation of volume-
specific pump elements permits a single unit
of the KFG or KFGS series to operate up to
three independent zones.
The KFGC series is capable of operating up to
four independent zones, depending on the
task. The system can be equipped with or
without functionality to monitor pressure
build-up and reduction.
4.2 Setup and attachment
The pump unit should be installed in a place
protected from contamination, water splashes
and vibrations. It should, however, be easily
accessible so that all other installations can be
performed without difficulty and the device can
be filled easily.
The fill level of the reservoir must be easily
visible.
The unit is mounted in a vertical position.
Any assembly holes must be made according
to the diagram on the following page.
Design specifications and conditions of the
manufacturer and the object must be observed
when installing the pump unit.
A drilling jig can be ordered (order number
951-130-115).
During assembly and especially when drilling,
always pay attention to the following:
Existing supply lines must not be damaged
by assembly work.
Other units must not be damaged by
assembly work.
The product must not be installed within
range of moving parts.
The product must be installed at an
adequate distance from sources of heat.
Maintain safety clearances and comply
with local regulations for assembly and
accident prevention.
On the pump units' electrical connections, en-
sure that appropriate measures prevent inter-
ference between signals due to inductive, ca-
pacitive or electro-magnetic couplings.
Shielded cables must be used in places where
electrical interference fields can distort signal
transmissions despite separate laying of
cables.