Page 77
EN
Device display - three-digit LED display
Continuation of "Three-digit LED display" table
Display
Meaning
Statement
Control function
P
ressure
S
witch
Pressure switch
(single-line systems)
L
ow
L
evel fault: fill
level too low.
F
ault
C
ycle
S
witch
fault: Piston detector
Fa
ult
P
ressure
S
witch
Fault: Pressure switch
O
peration
H
our Meter
Operational hours
counter
F
ault
H
our Meter
Fault-hours counter
Blo
ck mode
Pressure switch monitoring is
active.
The minimum fill level has been
reached in the reservoir.
No signal from piston detector
during pump cycle.
No signal from pressure switch
during pump cycle.
The values shown after this are
the number of hours the control
unit has operated.
The system pressure is moni-
tored by the pressure switch
during the pump cycle
The control unit is currently in
FAULT mode. The operational
sequence has been stopped.
The control unit is currently in
FAULT mode. The operational
sequence has been stopped.
The control unit is currently in
FAULT mode. The operational
sequence has been stopped.
The values shown after this are the number of fault hours, i.e.,
the amount of time the vehicle or machine was operated in FAULT
mode.
No signal from the piston detector. Unlike in normal mode, the
control unit is still the monitoring sequence. A fault notification is
issued if the fault remains for three pump cycles times.
9. Display and control unit
K
F
G
S