KFGC (CAN bus) fault notifications
Fault
Category
Possible cause
Rectification
Fill level
warning
Warning
Fill level in lubricant reservoir
falls to warning sensor
Break in sensor cable
Lubricant too soft
• Immediately refill with lubricant (see Chapter 4.4, page 22),
change pump element if necessary.
• Replace cable
• Replace lubricant
Fill level fault
Malfunction
Fill level in lubricant reservoir reaches
"min" mark
Break in sensor cable
• Immediately refill with lubricant (see Chapter 4.4, page 22)
• Replace the cable.
Cycle fault
Malfunction
Lubrication line defective
Progressive feeder blocked or
defective
Piston detector defective
Insufficient lubricant
Break in sensor cable
• Replace the defective line.
• Clean the feeder or replace it.
• Replace the piston detector.
• Immediately refill with lubricant (see Chapter 4.4, page 22),
change pump element if necessary.
• Replace the cable.
Pressure
build-up fault
Malfunction
Lubrication line defective
Pressure switch defective
Pressure relief valve blocked
or defective
Insufficient lubricant
Break in sensor cable
Lubricant too stiff
Main line cross-section too small
• Replace the defective line.
• Replace the pressure switch.
• Clean the valve or replace it.
• Immediately refill with lubricant (see Chapter 4.4, page 22),
change pump element if necessary.
• Replace the cable.
• Replace lubricant
• Increase main line cross-section.
Pressure
reduction fault
Malfunction
Pressure relief valve blocked or
defective
Pressure switch defective
Break in sensor cable
Lubricant too consistent
• Clean the valve or replace it.
• Replace the pressure switch.
• Replace the cable.
• Fill lubricant at suitable flow pressure, clean system.
15.2.7 Warning and malfunction indicator on KFGC (CAN bus) pump unit