4.3 Pump elements
4.3.1 KFG/KFGS pump elements
KFG and KFGS pump units can be equipped
with up to three pump elements. Each pump
element has a connector for, e.g., connecting
an independent progressive feeder. A grease
return can be attached in place of a pump
element.
Close any outlets which are not required using
a DIN 910-M20x1.5-5.8 screw plug with a
DIN 7603-A20x24-Al washer.
The pump elements must be ordered accor-
ding to the required delivery rate.
4.3.2 KFGC (CAN bus) pump elements
3/2 directional control valves can be employed
so that lubricant connections can also return
the lubricant into the reservoir from lubricant
outlets which are not required at the moment.
Close any outlets which are not required using
a DIN 910-M20x1.5-5.8 screw plug with a
DIN 7603-A20x24-Al washer.
4.3.3 Installation of a pump element
Pump units of the KFG, KFGS und KFGC
(CAN bus) series are generally delivered with
pump elements installed.
Perform the following to later add or replace a
pump element:
• Turn off pump unit.
• Loosen and remove screw plug.
1
2
3
Pump element replacement
Then perform the following:
• Loosen and remove pressure regulat-
ing valve (
2
) (or lubrication line (
3
)) on an
already mounted pump element (
1
).
• Loosen and remove mounted pump ele-
ment (
1
).
• Insert new pump element (
1
) into housing
hole and twist in by hand.
• Tighten pump element (
1
) at a torque
of 35 Nm.
• Switch on pump and leave running until
grease without bubbles discharges from the
pump element outlet.
• Reconnect pressure regulating valve (
2
)
(or lubrication line (
3
)) to the pump element
(
1
) and tighten at a torque of 25 Nm.
Possible layout of the three pump elements