4.5.3.3 Connectivity for counter operation
without system monitoring
Connector pin assignment in counter operation
PIN
Code
Assignment
1
M
- Supply voltage potential (0 V, GND)
2
L+
+ Supply voltage potential "Main machine switch ON"
3
MK
Machine contact
4
SL2
Indicator light "fault"
5
ZS
Piston detector "+"
6
ZS
Piston detector "signal"
7
SL1
Indicator light "pump ON"
4.5.3.4 Connectivity for counter operation
with system monitoring (progressive
centralized lubrication systems)
Programming: cPA, tCO, COP = OFF
M L+
(Industrie)
1
BN
KFGS...
F
2
3
4
5
6
7
X1
R
D
-BK
BU
PK
V
T-
G
N
MK
SL2
2,4 W
SL1
2,4 W
BK
BK
ZS
+
Programming: cPA, tCO, COP = CS
One pulse is counted each time the
operating voltage is switched on when
the machine contact is closed in
counter operation.
Control using machine pulses
(Counter mode
= load-dependent lubrication
)
The duration of the interval time is determined
by a pulse generator that sends pulses to the
control unit based on how long the machine
has been running. The control unit counts the
pulses that are received and starts the pump
after the pre-set number of pulses.
The pump cycle time is deined by a time
value. Both the number of pulses that deter-
mine the interval time and the pump cycle
time can be conigured.
The ill level monitoring unit is internally con
-
nected to the integrated pump control unit.
A fault notiication can be sent to the process
control level via indicator light SL2.
K
F
G
S
Assembly instructions