![SKF KFG Скачать руководство пользователя страница 84](http://html1.mh-extra.com/html/skf/kfg/kfg_assembly-instructions-manual_1287056084.webp)
Page 84
EN
11.1 Start programming mode
Programming mode can be identiied by
the lashing LED displays.
11.2 Change lubrication interval times
Note on step 2
If the 000 factory setting has been
changed, the current code must be
selected using the
keys and
conirmed using the
key.
Change lubrication interval times
Step
Key
Display
1
Display flashes
(000
=
factory setting)
Press for more than 2 s
2
Automatic display of first
parameter: "pause in timer operation"
Press briefly
"PAUSE" LED flashes
(confirm code)
3
Interval time 1 h (factory setting)
(display in hours)
Press briefly
4
Set new value
Example:
6.8 h = 6 h 48 min
5
Display next parameter
"pump cycle time in timer operation"
Press briefly
"CONTACT" LED flashes
(confirm new value)
6
Pump cycle time 4.0 min (factory setting)
Note the operating mode/set duration
Press briefly
- see Technical Data, Chapter 16
(display in minutes)
The working/interval times can be repro-
grammed to adapt the lubrication intervals and
the resulting lubricant quantities to speciic
requirements.
11. KFGS programming
K
F
G
S
11. KFGS programming
Содержание KFG
Страница 115: ......