4.5 Electrical connection
Warning!
Compare the operating voltage with the
speciications on the rating plate.
4.5.1 General conditions for electrical connections
KFG; KFGS; KFGC, general conditions for electrical connections
Nominal
Power
Power
Pump
Max.
voltage
consumption
consumption
starting current pre-connected fuse
(load-dependent)
(max.)
(approx. 20 ms)
24 VDC
1
)
1.25 A
2
)
< 2.5 A
4.5 A
4 A
3
)
4
)
12 VDC
1
)
2.4 A
2
)
< 5 A
9 A
6 A
3
)
4
)
115 VAC
N/A
5
)
1.5 A
20 A
C6A
230 VAC
N/A
5
)
0.9 A
40 A
C6A
KFGC (CAN bus)
Switching outputs:
Type: Solid-state output, short-circuit-proof and overload-proof
Max. current-carrying capacity:
- with simultaneous operation of 4 outputs 1.0 A
- with simultaneous operation of 2 outputs 1.25 A
- with operation of 1 output 1.5 A
Modes of operation:
- Single operation
- Parallel connection of multiple outputs while simultaneously
increasing output current
Signal inputs:
Type: digital solid-state input, short-circuit-proof
Connectivity:
- Switching contact, no detection of wire breakage
- Dual wire sensors (e.g., piston detector),
detection of wire breakage
1) Protective measures that must be applied for designated usage:
"Functional Extra Low Voltage,"
"Protective Extra Low Voltage“ (PELV)
Standards: EN 60204 Part 1: IEC 60204-1:
DIN VDE 0100 Part 410 / IEC 364-4-41: HD384.4.41
2) Typical value at ambient temperature = 25°C and operating pressure = 150 bar
3) Fuse per DIN 72581 T.3
4) Conductor: cross-section 1.5 mm
2
, length ≤ 12 m
5) No specification
Operating voltage
Operating voltage specification on rating plate
K
F
G
S
K
F
G
KF
G
C