![SKF KFG Скачать руководство пользователя страница 110](http://html1.mh-extra.com/html/skf/kfg/kfg_assembly-instructions-manual_1287056110.webp)
Page 110
EN
Continuation of "Technical Data" table
KFGC (CAN bus) data
Description Key data
Switching outputs
Type
Max. current-carrying capacity
Modes of operation
All types
Solid-state output, short-circuit-proof and overload-proof
• with simultaneous operation of 4 outputs: 1.0 A
• with simultaneous operation of 2 outputs: 1.25 A
• with operation of one output: 1.5 A
• Single operation
• Parallel connection of multiple outputs while simultaneously increasing output current
Signal inputs
Type
Connectivity
All types
digital solid-state input, short-circuit-proof
• Switching contact, no detection of wire breakage
• Dual wire sensors (e.g., piston detector), detection of wire breakage
Communication connections
CAN bus
Infrared
All types
SAE J1939
IrDA
Electrical data
Protection class
Operating mode/ON-time
according to VDE0530/DIN 41756
All types
according to DIN 40050, T9 IP5k5
S1 continuous operation
16. Technical data
KF
G
C
Содержание KFG
Страница 115: ......