Assembly instructions
4.4 Instructions on lubricant illing
Only ill using clean lubricant and an
appropriate illing device. Contaminated
lubricants can result in severe system
malfunction.
The lubricant reservoir is illed in different
ways based on the design.
4.4.1 Lubricant illing
Lubricant illing is performed using a
DIN 71412-AM10x1 conical head nipple (
1
)
and a conventional grease press.
The conical head nipple can be twisted onto
the position (
2
), for example to gain better
access. As an alternative, the connection (
2
)
can be used to mount a lubricant return or
iller coupling (see following page).
2
1
Filler sockets/lubricant return
R
A
P
R
M14
x
1,5
P
A
Pressure regulating valve with T connector
Connections for pressure regulating valve
with T connector
A
Connection for pipe Ø
P
Pipe thread for pump element
R
Grease discharge at overpressure
Cracking pressure........ 300 ± 20 bar
Nominal pipe sizes Ø .. 6, 8, 10 mm
pressure regulating valve
Pressure regulating valve
with T connector output
Pipe Ø
Cracking pressure Order number
[mm]
[bar]
6
300
161-210-038
6
200
161-210-032
8
300
161-210-039
8
200
161-210-031
10
300
161-210-016
10
200
161-210-030
Содержание KFG