6.2. Functional description in progressive
systems with KFGS pump unit
The general functional description for progres-
sive systems with a KFG pump unit also applies
for the design with KFGS pump control.
The control unit integrated into the pump
housing allows the following additional con-
iguration, monitoring and connectivity options:
I nterval time and pump cycle time can
be adjusted independently, including on
monitored systems
Recording of remaining intervals and
remaining lubrication times
Data backup in case of voltage failure
Non-volatile memory with PIN code
protection
Connectivity for inductive piston detector
to monitor the feeder function
Connectivity for external pushbutton
Internal ill level monitoring (W1 control);
lubrication cycle is halted and a fault sig-
nal is displayed if the ill level falls below
minimum
Diagnostics memory
Example of progressive system with KFGS pump unit
2
3
4
6
9
8
8
7
5
5
5
1
Progressive system with piston detector
1 KFGS unit
6 Piston detector
2 Power supply
7 Master feeder
3 Fault indicator light
8 Secondary feeder
4 Pump element with pressure regulating valve
9 Lubrication points
5 Lubrication lines
6. Functional description in progressive systems