Page 27
EN
Cable connection - see table with cable
colors
BN
WH
BU
BK
1/+24 V DC
2/ not assigned
3/-OV
4/NO
4.5.2.4 Fill level monitoring
Technical data
Fill level
. . . . . . . .Switch opens at min.
monitoring
fill level, fault Function
notification
and on wire breakage.
Operating voltage . . . .10 to 30 VDC
Continuous current . . .
≤ 200 mA
Internal power consumption 6 to 12 mA
Voltage drop . . . . . . . .
≤1.8 V at I
duration
EC Directives EN 6094752
Connection diagram . . M12x1 circular
connectors
Conducted interference per IEC 61000-4-6
(test level 3V). Radio interference is possible
between 2.4-2.6 MHz.
See assembly instructions on page 16
Warning!
The W2 ill level switch is not suit
-
able for greases ≥ NLGI grade 2.
Note
Customer-speciic designs are available
in addition to the two standard designs
shown. In this case, ill level switch W2
must be connected according to the
provided customer drawing.
Cable assignment (on fill level switch)
Color
Conductor
Use
code
coloring
BN
Brown
Supply voltage
BU
Blue
O V (0 volts)
BK
Black
NO-contact
WH
White
Not assigned
Pin/cable assignment (pump unit)
Pin
Color code Use
1
Brown
Supply voltage
2
White
Not assigned
3
Blue
O V (0 volts)
4
Black
NO-contact
Cable socket
1
) per
DIN EN 60947/IEC 947
1) Cable socket - see Accessories, Chapter 14
K
F
G
Assembly instructions
Type: W2 for grease NLGI Grade ≤ 1
BN
WH
BU
BK
1/+24 V DC
2/ not assigned
3/-OV
4/NO
1
2
4
3