4.5.5 KFGS 90-264 VAC series with
integrated control unit
The electrical connection is established via a
plug-in connector per DIN EN 17530-803 for
the power supply (on the front of the unit) and
a 4-pin M12x1 plug-in connector per
EN 60947-5-2 (on the underside of the unit).
Unneeded conductor ends on the cable
set must be individually insulated and
secured so that no short to ground can
occur.
4.5.5.1 Power supply 90-264 VAC
X1
1
2
3
L1
N
PE
90 - 264 V AC
47 - 440 Hz
C6A
F
)
1
Connector pin assignment for 90-264 VAC
PIN
Code Description
1
L1
Main machine switch ON
2
N
3
Not assigned
PE
Protective earth
1) = External control device "relay contact" "pump on"
Connector pin
assignment per
DIN EN 175 301-803
The "Timer operation with system
monitoring and ill level control" con
-
nectivity option (Chapter 6.5.5.1) is
also available in an advanced version
with a piston detector and fault signal.
A T connector with a special cable
adapter is required for this.
You can ind this, along with an il
-
lustration of the connection, under
Accessories, Chapter 17.
You can ind technical data and the
order number of the M12x1
circular connector (mating part for
circular plug socket) required by the
customer in brochure No. 1-1730,
"Electric Plug-and-Socket Connectors."
K
F
G
S
Assembly instructions
2
3
1