6) Enter a value for the
Surge Voltag
e based on your company and/or standards body
recommendations for the motor armature being tested. In this example, we use
500 volts.
7) Ensure that the
P-P EAR
box is checked.
8) Ensure that the
Enable
PP
box
is not
checked, then check the
ARM
box as shown in
the example below.
Figure 136.
Enable Baker ZTX by checking Arm box.
9) Immediately after you check the
Arm
box, the
Surge Test
setup window will
automatically change to the
Surge Test Armature
setup window as shown in the
example below.
NOTE
If the ARM check box is not visible, the Baker AWA-IV being used is not configured
to work with a Baker ZTX.
PUB CM/I4 71-015 EN V13.2 Static Motor Analyzer—Baker AWA-IV User Manual
137
Using the Baker ZTX with Baker AWA-IV analyzers