You should also note that you can use the
Dischg Time (min)
fields to specify a discharge
interval (in minutes) that will stop all testing for the requested time period to allow for
sufficient time for the motor to discharge. The feature is more commonly used to discharge
motors following DC HiPot testing.
CAUTION
If the windings are not allowed to completely discharge, a voltage can
develop on the motor leads that can be high enough to present a shock
hazard to personnel.
The
Surge Test
setup window is shown below. In this example, the
Surge Voltage
has been
set to 14200V and the
Enable PP
(power pack) box has been checked to turn on the power
pack for this test.
Figure 122.
Surge test setup—PP30.
13) Click on the
Close
button to return to the
Main
window,
Tests
tab.
14) Click on the
Save
button to save the new test information for this Test ID. The
Password may have to be entered again to make the
Save
button visible.
PUB CM/I4 71-015 EN V13.2 Static Motor Analyzer—Baker AWA-IV User Manual
121
Using power packs with 6/12 kV models
Содержание Baker AWA-IV 12 HO
Страница 1: ...SKF Static Motor Analyzer Baker AWA IV User manual...
Страница 2: ......
Страница 22: ...2 PUB CM I4 71 015 EN V13 2 Static Motor Analyzer Baker AWA IV User Manual About this manual...
Страница 126: ...106 PUB CM I4 71 015 EN V13 2 Static Motor Analyzer Baker AWA IV User Manual Test procedures...
Страница 202: ...182 PUB CM I4 71 015 EN V13 2 Static Motor Analyzer Baker AWA IV User Manual Database definition...
Страница 206: ...186 PUB CM I4 71 015 EN V13 2 Static Motor Analyzer Baker AWA IV User Manual...
Страница 213: ......