Ramp voltage test
The ramp voltage test is mostly used when testing generators. It gives information on the
contamination level with the winding. The ramp voltage test is performed for a
predetermined length of time at a specific voltage level. The voltage increases linearly on a
specific time scale.
As the test is operating, the key is to watch the current. If it remains linear with the voltage,
the winding is in good condition. If the current wavers up and down, the winding might be
contaminated. The figure below provides a graphical representation of this test. In the
illustration, the unstable line suddenly increases in voltage and current. If this occurs, it could
indicate an imminent overcurrent trip and a problem within the winding.
Figure 61.
Evaluating charging current during ramping.
PUB CM/I4 71-015 EN V13.2 Static Motor Analyzer—Baker AWA-IV User Manual