DC test failure types
Status
Failure type
Failure message
FAIL
Over voltage
Over Voltage Condition has been detected.
FAIL
Open ground
An open ground has been detected. Check
power cord outlet ground for continuity.
FAIL
Min Meg-Ohm
Test Result. Fail – MIN MEG-OHM. Meg-Ohm
value is less than the minimum tolerance.
FAIL
Min PI
PI test results: Fail – Min PI. PI Ratio is less
than minimum tolerance.
FAIL
Over current
Test result: FAIL – OVER CURRENT. An over
current trip was detected.
FAIL
No steps defined
No steps for Step-Voltage Test exist in this Test
ID.
FAIL
Low PRG HPT
voltage
The last step voltage is below the previous Meg-
Ohm/PI test voltage.
Surge test failure types
Status
Failure type
Failure message
FAIL
Open leads
Test Results: Fail – OPEN LEADS. Open leads
detected.
FAIL
Over voltage
Over Voltage Condition has been detected.
FAIL
Open ground
An open ground has been detected. Check
power cord power outlet ground for continuity.
FAIL
ppEAR Limit
Surge test results: Fail – ppEAR LIMIT. Pulse-
to-Pulse EAR%.
FAIL
L-L EAR
Surge Test Result: Fail – L-L EAR Lead- to-Lead
EAR % is out of tolerance.
CAUTION
Unequal zero
crossings
Test results: Caution – UNEQUAL ZERO
CROSSINGS Waveforms do not have the same
number of zero crossings.
184
PUB CM/I4 71-015 EN V13.2 Static Motor Analyzer—Baker AWA-IV User Manual
Содержание Baker AWA-IV 12 HO
Страница 1: ...SKF Static Motor Analyzer Baker AWA IV User manual...
Страница 2: ......
Страница 22: ...2 PUB CM I4 71 015 EN V13 2 Static Motor Analyzer Baker AWA IV User Manual About this manual...
Страница 126: ...106 PUB CM I4 71 015 EN V13 2 Static Motor Analyzer Baker AWA IV User Manual Test procedures...
Страница 202: ...182 PUB CM I4 71 015 EN V13 2 Static Motor Analyzer Baker AWA IV User Manual Database definition...
Страница 206: ...186 PUB CM I4 71 015 EN V13 2 Static Motor Analyzer Baker AWA IV User Manual...
Страница 213: ......