PI/DA
—The
DC Tests
setup window will switch its focus to the PI/DA tests column.
Because the Test ID in this example was set up for a Dielectric Absorption (DA) test,
the duration of the test is three minutes (180 seconds). At end of the test, if no
failures occur, the software will continue with the next series.
•
HiPot/Step-Voltage/Ramp-Voltage
—The test will begin automatically. For Step-
Voltage testing, a new window automatically appears to display the test results in
progress. Preset by the example Test ID, the voltage is ramped up to 2000 volts in
500-volt steps, and held for 60 seconds at each step. If the analyzer detects a low
MegOhm reading or a overcurrent trip, testing will immediately stop, and the leads
will be discharged and grounded. You will be given the choice to repeat the test, stop
all testing, or continue to the next test.
Figure 95.
Step -Voltage test window—called automatically from DC Tests process.
If no failures are found during this test, the analyzer will close the
Step-Voltage Test
and
DC
Tests
setup windows, and continue to the Surge test.
PUB CM/I4 71-015 EN V13.2 Static Motor Analyzer—Baker AWA-IV User Manual
93
Test procedures
Содержание Baker AWA-IV 12 HO
Страница 1: ...SKF Static Motor Analyzer Baker AWA IV User manual...
Страница 2: ......
Страница 22: ...2 PUB CM I4 71 015 EN V13 2 Static Motor Analyzer Baker AWA IV User Manual About this manual...
Страница 126: ...106 PUB CM I4 71 015 EN V13 2 Static Motor Analyzer Baker AWA IV User Manual Test procedures...
Страница 202: ...182 PUB CM I4 71 015 EN V13 2 Static Motor Analyzer Baker AWA IV User Manual Database definition...
Страница 206: ...186 PUB CM I4 71 015 EN V13 2 Static Motor Analyzer Baker AWA IV User Manual...
Страница 213: ......