Data tab—Step/Ramp-Voltage view
Clicking on the
Step/Ramp-Voltage
tab displays the Step Voltage test data in both graphical
and tabular form. The graph defaults to plotting current vs. voltage.
The red triangles indicate the current level at the end of each step.
Clicking on the
Current vs. Voltage
or
Current/Voltage vs. Time
radio buttons determines
what will be plotted on the graph and in the table.
Voltage is displayed in blue and real-time current in red. The green line with triangle markers
indicate the current at the end of each step.
Figure 54.
Step/ramp Voltage
view showing current vs. voltage.
NOTE
The large swings of the red real-time current lines show the motor’s charging
current while ramping up voltage. These large swings do not indicate an insulation
problem.