- Check if one Sensor Monitors in the system is in the Master mode.
- Check if the IP port is specified for sending the data to Extractor/Tracker. This port must
be the same as specified in LAN,
NavigationInPort
parameter of the
VarpPCI.ini file
located in C:\Program Files\Maris\PC Radar Kit\ on the computer where the PC Radar
Kit hardware is installed.
4.
If ARPA 2000 shows proper navigational parameters, but the radar overlay is not correctly
arranged:
- Activate the System dialog in the ARPA 2000. Refer to the ARPA 2000 user manual.
- Click the
►
or
◄
buttons until the Extractor parameters page is displayed
- Modify the
Headup
parameter to adjust the orientation of the radar overlay. Ensure to
check it in ECDIS after each modification.
- Modify
Sync Delay
parameter to adjust the distances to objects. The distance to
certain radar echo is back-proportional to the Sync Delay value.