These registers determine the OOF alarm set threshold for IN3, IN2, IN1 and IN0 when the fast control is enabled.
The value in each of the register is (1+ value) x 1000 ppm. ClockBuilder Pro
is used to determine the values for
these registers.
Register 0x004A-0x004D Out of Frequency Clear Threshold
Reg Address
Bit Field
Type
Name
Description
0x004A
7:0
R/W
OOF0_CLR_THR
OOF Clear threshold. Range is up to
500 ppm in steps of 1/16 ppm
0x004B
7:0
R/W
OOF1_CLR_THR
OOF Clear threshold. Range is up to
500 ppm in steps of 1/16 ppm
0x004C
7:0
R/W
OOF2_CLR_THR
OOF Clear threshold. Range is up to
500 ppm in steps of 1/16 ppm
0x004D
7:0
R/W
OOF3_CLR_THR
OOF Clear threshold. Range is up to
500 ppm in steps of 1/16 ppm
Register 0x004E-0x04F OOF Detection Windows
Reg Address
Bit Field Type
Setting Name
Description
0x004E
2:0
R/W
OOF0_DETWIN_SEL
Values calculated by CBPro
0x004E
6:4
R/W
OOF1_DETWIN_SEL
0x004F
2:0
R/W
OOF2_DETWIN_SEL
0x004F
6:4
R/W
OOF3_DETWIN_SEL
Register 0x0051-0x0054 Fast Out of Frequency Set Threshold
Reg Address
Bit Field
Type
Name
Description
0x0051
3:0
R/W
FAST_OOF0_SET_THR
(1+ value) x 1000 ppm
0x0052
3:0
R/W
FAST_OOF1_SET_THR
(1+ value) x 1000 ppm
0x0053
3:0
R/W
FAST_OOF2_SET_THR
(1+ value) x 1000 ppm
0x0054
3:0
R/W
FAST_OOF3_SET_THR
(1+ value) x 1000 ppm
Register 0x0055-0x0058 Fast Out of Frequency Clear Threshold
Reg Address
Bit Field
Type
Name
Description
0x0055
3:0
R/W
FAST_OOF0_CLR_THR
(1+ value) x 1000 ppm
0x0056
3:0
R/W
FAST_OOF1_CLR_THR
(1+ value) x 1000 ppm
0x0057
3:0
R/W
FAST_OOF2_CLR_THR
(1+ value) x 1000 ppm
0x0058
3:0
R/W
FAST_OOF3_CLR_THR