Si5345-44-42-D-RM
Si5345
Rev. 1.0
83
Si5345C-A-GM.
Applies to a “base” or “non-custom” OPN device. Base devices are factory pre-programmed to a specific base part
type (e.g., Si5345 but
exclude
any user-defined frequency plan or other user-defined operating characteristics
selected in ClockBuilder Pro.
Bit 1 is the LOS status monitor for the XTAL or REFCLK at the XA/XB pins.
Note that each bit corresponds to the input. The LOS and OOF bits are not sticky.
Input 0 (IN0) corresponds to LOS 0x000D [0], OOF 0x000D [4]
Input 1 (IN1) corresponds to LOS 0x000D [1], OOF 0x000D [5]
Input 2 (IN2) corresponds to LOS 0x000D [2], OOF 0x000D [6]
Input 3 (IN3) corresponds to LOS 0x000D [3], OOF 0x000D [7]
Register 0x000B I
2
C Address
Reg Address
Bit Field
Type
Setting Name
Description
0x000B
6:2
R/W
I2C_ADDR
The upper 5 bits of the 7 bit I
2
C address.
The lower 2 bits are controlled by the A1 and A0
pins.
Register 0x000B I
2
C Address
Reg Address
Bit Field
Type
Setting Name
Description
0x000B
6:2
R/W
I2C_ADDR
The upper 5 bits of the 7 bit I
2
C address.
The lower 2 bits are controlled by the A1
and A0 pins.
Register 0x000C Internal Status Bits
Reg Address
Bit Field
Type
Name
Description
0x000C
0
R
SYSINCAL
1 if the device is calibrating.
0x000C
1
R
LOSXAXB
1 if there is no signal at the XAXB pins.
0x000C
2
R
0x000C
3
R
0x000C
4
R
0x000C
5
R
SMBUS_TIMEOUT
1 if there is an SMBus timeout error.
Register 0x000D Out-of-Frequency (OOF) and Loss-of Signal (LOS) Alarms
Reg Address
Bit Field
Type
Name
Description
0x000D
3:0
R
LOS
1 if the clock input is currently LOS
0x000D
7:4
R
OOF
1 if the clock input is currently OOF